Had a low battery event on Christmas Eve. Towed home and a few days later I checked voltage and balanced the back. Chart below. The Quick-Charger brand charger is not working correctly I believe and the pack was past due for balance.
| December 24 Battery Low Voltage Event, Vehicle towed home and Voltage checked a few days later with a light load with fan on high and lights | |||||
| Battery # | First Test | Volts Loaded | Charged | Discharged | |
| Front Box | 0 | 2.47 | |||
| 1 | 2.58 | ||||
| 2 | 2.71 | ||||
| 3 | 2.52 | X | |||
| 4 | 2.58 | ||||
| 5 | 2.73 | ||||
| 6 | 2.85 | X | |||
| 7 | 2.87 | X | |||
| 8 | 2.70 | ||||
| 9 | 2.76 | X | |||
| 10 | 2.81 | X | |||
| 11 | 2.78 | X | |||
| Rear Box | 12 | 2.70 | |||
| 13 | 2.73 | ||||
| 14 | 2.20 | X | |||
| 15 | 1.90 | X | |||
| 16 | 2.59 | ||||
| 17 | 2.71 | ||||
| 18 | 1.86 | X | |||
| 19 | 2.64 | ||||
| 20 | 2.26 | X | |||
| 21 | 2.74 | ||||
| 22 | 2.78 | ||||
| 23 | 2.74 | ||||
| 24 | 2.74 | ||||
| 25 | 2.00 | X | |||
| 26 | 2.65 | ||||
| 27 | 2.20 | X | |||
| 28 | 1.61 | X | |||
| 29 | 1.51 | X | |||
| 30 | 2.70 | ||||
| 31 | 1.60 | X | |||
| 32 | 1.54 | X | |||
| 33 | 1.66 | X | |||
| 34 | 2.78 | ||||
| 35 | 2.73 | ||||
| Center Box | 36 | 2.76 | X | ||
| 37 | 2.20 | X | |||
| 38 | 2.77 | X | |||
| 39 | 2.66 | ||||
| 40 | 1.80 | X | |||
| 41 | 2.70 | ||||
| 42 | 2.67 | ||||
| 43 | 2.74 | X | |||
| 44 | 0.44 | X | |||
| 45 | 2.64 | ||||
| 46 | 2.47 | X | |||
| 47 | 2.64 |